EXE 600 Series

    Spécifications techniques

    Specifications

    EXE 602 E

    EXE 660 B

    Input

    11 µAPP

    Electrical Connection

    M23 flange socket (female) 9-pin

    Cable length

    ≤ 30 m for IEncoder ≤ 120 mA

    Interpolation1)

    Without, 5-fold

    25-fold, 50-fold, 100-fold, 200-fold, 400-fold

    Input frequency1) for interpolation

    Nominal values2)

    Without

    50 kHz

    5-fold

    25 kHz

    25-fold

    50 kHz

    50 kHz

    25 kHz

    12.5 kHz

    50-fold

    50 kHz

    25 kHz

    12.5 kHz

    6.25 kHz

    100-fold

    25 kHz

    12.5 kHz

    6.25 kHz

    3.12 kHz

    200-fold

    12.5 kHz

    6.25 kHz

    3.12 kHz

    1.56 kHz

    400-fold

    6.25 kHz

    3.12 kHz

    1.56 kHz

    0.78 kHz

    Output

      TTL (unclocked)

    TTL (clocked)

    Electrical connection

    M23 flange socket (male) 12-pin

    Cable length

    ≤ 100 m (Uas ≤ 50 m)

    Edge separation a

    ≥ 2.500 µs

    ≥ 0.500 µs

    ≥ 0.075 µs

    ≥ 0.175 µs

    ≥ 0.370 µs

    ≥ 0.760 µs

    Reference mark signal1)

    Pulse width 90° elec. or ungated (only when without interpolation) or 270° elec.

    Fault indication1)

    through fault detection signal Uas or, in addition, Ua1/Ua2 high impedance

    Power supply

    5 V ± 5%

    Current consumption3)

    ≤ 90 mA

    ≤ 120 mA

    Operating temperature

    Storage temperature

    0 °C to 70 °C

    –30 °C to 80 °C

    Vibration 50 to 2000 Hz

    Shock 11 ms

    ≤ 10 m/s2

    ≤ 300 m/s2

    Protection

    IP 65

    Weight

    0.7 kg

    Bold: These preferred versions are available on short notice

    1) Adjustable

    2) The actual input frequency can be up to 5 % lower. Exceeding this limit results in failure

    3) Not including the current consumption of the encoder (see the corresponding brochure) and without output load
    (80 mA with recommended input circuitry)