ERO 6000

    Spécifications techniques

    Scanning head

    AK ERO 6080

    AK ERO 6070

    Interface

    1 VPP

    TTL x 5

    TTL x 10

    TTL x 50

    Reference mark signal

    Square-wave pulse

    Integrated interpolation*

    5-fold

    10-fold

    50-fold

    Cutoff frequency –3 dB

    200 kHz

    Scanning frequency

    200 kHz

    100 kHz

    25 kHz

    Edge separation a

    0.220 µs

    0.220 µs

    0.175 µs

    Electrical connection

    Cable 3 m with male D-sub connector (15-pin), interface electronics for ERO 6070 in the connector

    Cable length

    30 m

    Voltage supply

    5 V DC ± 0.25 V

    Current requirement

    < 100 mA (without load)

    < 200 mA (without load)

    Vibration 55 to 2 000 Hz

    Shock 6 ms

    200 m/s2 (EN 60 068-2-6)

    500 m/s2 (EN 60 068-2-27)

    Operating temperature

    0 °C to 50 °C

    Weight Scanning head

    (approx.) Connector

    Cable

    6 g (without cable)

    32 g

    22 g/m

    6 g (without cable)

    140 g

    22 g/m

    Graduated disk

    TKN ERO 6000

    Measuring standard

    METALLUR graduation on glass

    Signal periods*

    9 000

    18 000

    Accuracy of graduation

    ± 5”

    ± 3,5”

    Position error per signal period1)

    ± 2”

    ± 1”

    Reference marks

    One

    Hub inside diameter

    25 mm

    95 mm

    Circular scale outside diameter

    71 mm

    150 mm

    Mech. permissible speed

    1 600 min-1

    800 min-1

    Moment of inertia

    44 x 10-6 kgm2

    1.1 x 10-3 kgm2

    Permissible axial motion

    0.1 mm

    Protection EN 60 529

    IP 00

    Weight (approx.)

    84 g

    323 g

    * Please select when ordering

    1) The position error within one signal period and the accuracy of the graduation result together in the encoder-specific error; for additional error through mounting and the bearing of the measured shaft, see Measuring accuracy