LIC 2117 / LIC 2197

    Spécifications techniques

    Linear scale

    LIC 2107

    Measuring standard

    Coefficient of linear expansion

    Steel scale tape with absolute track

    αtherm  10 · 10–6 K–1

    Accuracy grade

    ±15 µm

    Measuring length ML* in mm

    120 320 520 770 1020 1220 1520 2020 2420 3020

    (Larger measuring lengths upon request)

    Mass Scale tape

    Scale-tape carrier

    20 g/m

    70 g/m

    Scanning head

    LIC 211 scanning head

    AK LIC 219 F

    AK LIC 219 M

    AK LIC 219 P

    Interface

    EnDat 2.2

    Fanuc Serial Interface

    αi interface

    Mitsubishi high speed interface

    Panasonic
    Serial Interface

    Ordering designation*

    EnDat22

    Fanuc05

    Mit03-4

    Mit02-2

    Pana01

    Measuring step*

    0.1 µm (100 nm)

    0.05 µm (50 nm)

    Calculation time tcal

    Clock frequency

    5 µs

    16 MHz

    Traversing speed1)

    600 m/min

    Interpolation error

    ±2 µm

    Electrical connection*

    Cable, 1 m or 3 m with 8-pin M12 coupling (male) or 15-pin D-sub connector (male)

    Cable length
    (with HEIDENHAIN cable)

    100 m

    50 m

    30 m

    50 m

    Voltage supply

    DC 3.6 V to 14 V

    Power consumption1) (max.)

    At 3.6 V: 800 mW

    At 14 V: 900 mW

    At 3.6 V: 950 mW

    At 14 V: 1050 mW

    Current consumption (typical)

    At 5 V: 75 mA (without load)

    At 5 V: 95 mA (without load)

    Vibration 55 Hz to 2000 Hz

    Shock 6 ms

    500 m/s2 (EN 60 068-2-6)

    1000 m/s2 (EN 60 068-2-27)

    Operating temperature

    –10 °C to 70 °C

    Mass Scanning head

    Connecting cable

    Connector

    18 g (without cable)

    20 g/m

    M12 coupling: 15 g; D-sub connector: 32 g

    * Please select when ordering

    1) See General electrical information in the brochure Interfaces for HEIDENHAIN Encoders