LC 100 series

    Spécifications techniques

    Specifications

    LC 195 S

    LC 195 S

    LC 195 F

    LC 195 M

    Measuring standard

    Coefficient of linear expansion

    DIADUR glass scale with absolute track and incremental track, grating period 20 µm

    αtherm  8 x 10–6 K–1

    Accuracy grade*

    ±3 µm up to 3040 mm measuring length; ±5 µm

    Measuring length ML* in mm

    140 240 340 440 540 640 740 840 940 1040 1140 1240 1340 1440 1540 1640 1740 1840 2040 2240 2440 2640 2840 3040 3240 3440 3640 3840 4040 4240

    Functional safety

    for applications up to

    • SIL-2 according to EN 61 508
    • Category 3, PL ''d” as per
      EN ISO 13 849-1:2008

    PFH

    25 x 10–9; ML > 3040 mm: 40 x 10–9

    (up to 1000 m above sea level)

    Safe position1)

    Encoder: ±550 μm; ML > 3040 mm: ±2050 µm

    (safety-related measuring step SM = 220 μm)

    Mechanical connection: fault exclusions for loosening of the housing and scanning unit (page 21)

    Interface

    DRIVE-CLiQ

    Fanuc Serial Interface/αi interface

    Mitsubishi high speed interface

    Ordering designation

    DQ01

    Fanuc05

    Mit03-04

    Measuring step

    At ±3 µm

    At ±5 µm

    0.001 µm

    0.010 µm

    αi interface/α interface

    0.00125 µm/0.010 µm

    0.0125 µm/0.050 µm

    0.001 µm

    0.010 µm

    Clock freq. (calc. time tcal)

    Electrical connection

    Separate adapter cable (1 m/3 m/6 m/9 m) connectable on both sides to mounting block

    Cable length

    30 m2)

    50 m

    30 m

    Voltage supply

    DC 10 V to 28.8 V

    DC 3.6 V to 14 V

    Power consumption (max.)

    10 V: 1.5 W; 28.8 V: 1.7 W

    3.6 V: 1.1 W; 14 V: 1.3 W

    Traversing speed

    180 m/min (max. acceleration 100 m/s2)

    Required moving force

    4 N

    Vibration 55 Hz to 2000 Hz
    effecting the

    Shock 11 ms

    Housing: 200 m/s2 (EN 60 068-2-6)

    Scanning unit: 200 m/s2 (EN 60 068-2-6)

    300 m/s2 (EN 60 068-2-27)

    Operating temperature

    0 °C to 50 °C

    Protection EN 60 5293)

    IP53 when installed according to instructions in the brochure, IP64 with sealing air from DA 400

    Mass

    0.55 kg + 2.9 kg/m measuring length

    * Please select when ordering

    1) Further tolerances may occur in subsequent electronics after position value comparison (contact manufacturer of subsequent electronics)

    2) Larger cable lengths upon request

    3) In the application the LC must be protected from the intrusion of particles and liquids