CNC PILOT 640

    Spécifications techniques

    Specifications

    Components

    MC main computer with TFT color flat panel display (19-inch), or

    MC main computer with integrated TFT color flat-panel display (15.6 inch) for multitouch operation

    CC, UEC or UMC controller unit

    TE operating panel (19-inch or 15.6-inch) with

    • integrated machine operating panel
    • feed-rate and spindle override potentiometer
    • with electronic handwheel available (only for 19-inch version)

    Operating system

    HEROS 5 real-time operating system for machine control

    NC program memory

    1.8 GB (on CFR compact flash memory card)

    Input resolution and display step

    X axis: 0.5 µm, diameter: 1 µm

    U, V, W, Y, Z axis: 1 µm

    B, C1/C2 axis: 0.001°

    Interpolation

    Straight line: in 2 principal axes (max. ±100 m), optional in 3 principal axes

    Circle: In 2 axes (radius max. 999 m), optional additional linear interpolation in the third axis

    C1/C2 axis: interpolation of X and Z linear axes with the C1/C2 axis (option)

    B axis: 5-axis interpolation between X, Z, Y, B, and C axes (option)

    Feed rate

    mm/min or mm/revolution

    Constant surface speed

    Max. feed rate (maximum 60 000/pole pair number × spindle pitch) with fPWM = 5000 Hz

    Spindle

    Maximum of 60 000 rpm (with option 49, max. 120 000 rpm) for motors with one pole pair

    Axis feedback control

    Integrated digital drive control for synchronous and asynchronous motors

    Position loop resolution: Signal period of the position encoder/1024

    Cycle time of position controller: 0.2 ms

    Cycle time of speed controller: 0.2 ms

    Cycle time of current controller: minimum 0.05 ms

    Error compensation

    Linear and nonlinear axis error, backlash, reversal peaks during circular movements

    Static friction

    Data interfaces

    Gigabit Ethernet interface 1000BASE-T

    4 x USB (1 x front USB 2.0; 3 x back panel USB 3.0)

    Diagnostics

    Fast and simple troubleshooting through integrated diagnostic aids

    Ambient temperature

    Operation: In electrical cabinet: 5 °C to 40 °C
    In operating panel: 0 °C to 50 °C

    Storage: –20 °C to 60 °C